TY - JOUR
T1 - Reverse remodeling of tricuspid valve morphology and function in chronic thromboembolic pulmonary hypertension patients following pulmonary thromboendarterectomy
T2 - a cardiac magnetic resonance imaging and invasive hemodynamic study
AU - Frederiksen, Christian Alcaraz
AU - Waziri, Farhad
AU - Ringgaard, Steffen
AU - Mellemkjær, Søren
AU - Clemmensen, Tor Skibsted
AU - Hjortdal, Vibeke Elisabeth
AU - Nielsen, Sten Lyager
AU - Poulsen, Steen Hvitfeldt
N1 - © 2021. The Author(s).
PY - 2021/12
Y1 - 2021/12
N2 - BACKGROUND: To investigate changes in tricuspid annulus (TA) and tricuspid valve (TV) morphology among chronic thromboembolic pulmonary hypertension (CTEPH) patients before and 12 months after pulmonary thromboendarterectomy (PEA) and compare these findings to normal control subjects.METHODS: 20 CTEPH patients and 20 controls were enrolled in the study. The patients were examined with echocardiography, right heart catherization and cardiac magnetic resonance imaging prior to PEA and 12 months after.RESULTS: Right atrium (RA) volume was significantly reduced from baseline to 12 months after PEA (30 ± 9 vs 23 ± 5 ml/m2, p < 0.005). TA annular area in systole remained unchanged (p = 0.11) and was comparable to controls. The leaflet area, tenting volume and tenting height in systole were significantly increased at baseline but decreased significantly with comparable values to controls after 12 months (p < 0.005). There was correlation between the changes of right ventricular-pulmonary artery coupling and changes of TV tenting height (r = - 0.54, p = 0.02), TV tenting volume (r = - 0.73, p < 0.001) and TV leaflet area (- 0.57, p = 0.01) from baseline to 12 months after PEA. Tricuspid regurgitation jet area/RA area was significantly (p < 0.01) reduced from baseline (30 ± 13%) to 12 months after PEA (9 ± 10%).CONCLUSION: In CTEPH patients selected for PEA, TV tenting height, volume and valve area are significantly increased whereas annulus size and shape are less affected. The alterations in TV morphology are fully reversed after PEA and correlates to improvements of right ventricular-pulmonary arterial coupling.
AB - BACKGROUND: To investigate changes in tricuspid annulus (TA) and tricuspid valve (TV) morphology among chronic thromboembolic pulmonary hypertension (CTEPH) patients before and 12 months after pulmonary thromboendarterectomy (PEA) and compare these findings to normal control subjects.METHODS: 20 CTEPH patients and 20 controls were enrolled in the study. The patients were examined with echocardiography, right heart catherization and cardiac magnetic resonance imaging prior to PEA and 12 months after.RESULTS: Right atrium (RA) volume was significantly reduced from baseline to 12 months after PEA (30 ± 9 vs 23 ± 5 ml/m2, p < 0.005). TA annular area in systole remained unchanged (p = 0.11) and was comparable to controls. The leaflet area, tenting volume and tenting height in systole were significantly increased at baseline but decreased significantly with comparable values to controls after 12 months (p < 0.005). There was correlation between the changes of right ventricular-pulmonary artery coupling and changes of TV tenting height (r = - 0.54, p = 0.02), TV tenting volume (r = - 0.73, p < 0.001) and TV leaflet area (- 0.57, p = 0.01) from baseline to 12 months after PEA. Tricuspid regurgitation jet area/RA area was significantly (p < 0.01) reduced from baseline (30 ± 13%) to 12 months after PEA (9 ± 10%).CONCLUSION: In CTEPH patients selected for PEA, TV tenting height, volume and valve area are significantly increased whereas annulus size and shape are less affected. The alterations in TV morphology are fully reversed after PEA and correlates to improvements of right ventricular-pulmonary arterial coupling.
KW - Cardiac magnetic resonance imaging
KW - Chronic thromboembolic pulmonary hypertension
KW - Tricuspid valve
U2 - 10.1186/s12872-021-02248-3
DO - 10.1186/s12872-021-02248-3
M3 - Journal article
C2 - 34535073
SN - 1471-2261
VL - 21
JO - BMC Cardiovascular Disorders
JF - BMC Cardiovascular Disorders
IS - 1
M1 - 450
ER -