Evaluation of 2- and 3-dimensional anatomic parameters of C-shaped root canals with cone beam computed tomography, microcomputed tomography, and nanocomputed tomography

Miguel Angel Ventura Molina, Giovane Oliveira Silva, Amanda Pelegrin Candemil, Rafael Verardino de Camargo, Ruben Pauwels, Reinhilde Jacobs, Manoel Damião Sousa-Neto, Jardel Francisco Mazzi-Chaves*

*Corresponding author for this work

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

Abstract

Objective: The objective of this study was to evaluate 2-dimensional (2D) and 3D morphometric parameters of C-shaped root canals on cone beam computed tomography (CBCT) and microcomputed tomography (microCT) images using nanocomputed tomography (nanoCT) as the reference standard. Study Design: Sixty mandibular molars with C-shaped canals were individually scanned using nanoCT and microCT. Cone beam computed tomography acquisitions were then performed with 4 CBCT systems, using high and standard resolutions. The 2D parameters of roundness and major and minor diameters were obtained in the cross sections of the root canals at 1, 2, and 3 mm from the root apex. The 3D parameters of surface area, volume, and structure model index were measured considering the entire extension of the root canals. Absolute error (AE) in measurement was calculated against the nanoCT values. Data were statistically analyzed with the Shapiro-Wilk test and analysis of variance (α = 0.05). Results: No significant differences in AE were discovered for the 2D parameters among microCT and the CBCT scans. The AE values for the 3D parameters of volume and surface area were significantly smaller in microCT compared to all CBCT units (P < .05). Significantly lower AE values for surface area were observed in high resolution compared to standard resolution for all CBCT units (P < .05). Structure model index did not differ significantly among microCT and all CBCT protocols. Conclusions: Cone beam computed tomography images showed accuracy for evaluating 2D parameters and over- and underestimation for 3D parameters.

Original languageEnglish
JournalOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Volume136
Issue6
Pages (from-to)759-768
Number of pages10
ISSN2212-4403
DOIs
Publication statusPublished - Dec 2023

Keywords

  • Cone-Beam Computed Tomography/methods
  • Dental Pulp Cavity/diagnostic imaging
  • Humans
  • Mandible/diagnostic imaging
  • Molar/diagnostic imaging
  • Tooth Root
  • X-Ray Microtomography

Fingerprint

Dive into the research topics of 'Evaluation of 2- and 3-dimensional anatomic parameters of C-shaped root canals with cone beam computed tomography, microcomputed tomography, and nanocomputed tomography'. Together they form a unique fingerprint.

Cite this