Effects of nongaussian diffusion on “isotropic diffusion“ measurements: an ex-vivo microimaging and simulation study

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

  • Sune Jespersen
  • Jonas Lynge Olesen
  • Andrada Ianuş, Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal., UCL, PortugalNoam Shemesh, Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal., Portugal
Designing novel diffusion-weighted pulse sequences to probe tissue microstructure beyond the conventional Stejskal-Tanner family is currently of broad interest. One such technique, multidimensional diffusion MRI, has been recently proposed to afford model-free decomposition of diffusion signal kurtosis into terms originating from either ensemble variance of isotropic diffusivity or microscopic diffusion anisotropy. This ability rests on the assumption that diffusion can be described as a sum of multiple Gaussian compartments, but this is often not strictly fulfilled. The effects of nongaussian diffusion on single shot isotropic diffusion sequences were first considered in detail by de Swiet and Mitra in 1996. They showed theoretically that anisotropic compartments lead to anisotropic time dependence of the diffusion tensors, which causes the measured isotropic diffusivity to depend on gradient frame orientation. Here we show how such deviations from the multiple Gaussian compartments assumption conflates orientation dispersion with ensemble variance in isotropic diffusivity. Second, we consider additional contributions to the apparent variance in isotropic diffusivity arising due to intracompartmental kurtosis. These will likewise depend on gradient frame orientation. We illustrate the potential importance of these confounds with analytical expressions, numerical simulations in simple model geometries, and microimaging experiments in fixed spinal cord using isotropic diffusion encoding waveforms with 7.5 ms duration and 3000 mT/m maximum amplitude.
Original languageDanish
JournalJournal of Magnetic Resonance
Volume300
Pages (from-to)84-94
ISSN1090-7807
DOIs
Publication statusPublished - 2019

See relations at Aarhus University Citationformats

ID: 142900321