Does a titanium sleeve reduce the frequency of pseudotumors in metal-on-metal total hip arthroplasty at 5–7 years follow-up?

Translated title of the contribution: Un manchon interposé de titane réduit-il la fréquence des pseudo-tumeurs après arthrosplatie totale de hanche métal-métal au recul de 5–7 ans

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

9 Citations (Scopus)

Abstract

Introduction Little is known about pseudotumor frequency and risk factors for pseudotumor formation among different types of metal-on-metal (MoM) hip arthroplasties. A lower release of chromium and cobalt have been reported in MoM hip arthroplasties with a titanium sleeve compared to MoM designs without a titanium sleeve, but yet it is unknown whether a titanium sleeve reduces the pseudotumor frequency. We conducted a cross-sectional study to investigate: 1) pseudotumor frequency, 2) risk factors of pseudotumor formation 3) and correlations between pseudotumors, serum metal-ions, implant position, and clinical symptoms. Hypothesis We expected a lower pseudotumor frequency in MoM hip articulation with a titanium sleeve than reported in MoM hip articulation designs using chromium-cobalt sleeve. Materials and method A consecutive series of 41 patients/49 hips (31 males), mean age 52 (28–68) years, participated in a 5.5 ± 0.5 (4–6.5) year follow-up study of their M2a_Magnum hip articulation (Biomet Inc., Warsaw, Indiana, USA). Patients were evaluated with magnetic resonance imaging (MRI), measurements of serum metal-ions, plain radiographs, and clinical outcome measures of Harris Hip Score (HHS) and Oxford Hip Score (OHS). Results Eighteen of 47 hips (38%) had MRI-verified pseudotumors, all cystic, with a mean dimension of 10.6 × 25.6 × 41 mm. Digital measurements on plain radiographs revealed a higher cup anteversion in patients with a pseudotumor of mean 28.4° ± 5.05° compared to mean 23.5° ± 6.5° in patients without a pseudotumor (P = 0.009). Serum metal-ion concentrations, acetabular cup inclination and measures of HHS and OHS were similar between patients with and without a pseudotumor (P > 0.46). Conclusion At 5.5 ± 0.5 years after surgery, MRI-verified cystic pseudotumors were frequently observed in M2a_Magnum hip articulations despite the use of titanium sleeves. The pseudotumors were related to high cup anteversion angles but not related to high serum metal-ions or clinical symptoms. Level of evidence IV: cross-sectional study.

Translated title of the contributionUn manchon interposé de titane réduit-il la fréquence des pseudo-tumeurs après arthrosplatie totale de hanche métal-métal au recul de 5–7 ans
Original languageMultiple languages
JournalOrthopaedics & Traumatology: Surgery & Research
Volume102
Issue8
Pages (from-to)1035–1041, 739
Number of pages7
ISSN1877-0568
DOIs
Publication statusPublished - 1 Dec 2016

Keywords

  • Clinical outcome measures
  • Magnetic resonance imaging
  • Metal-on-metal total hip arthroplasty
  • Pseudotumor
  • Serum metal-ion levels
  • Titanium sleeve

Fingerprint

Dive into the research topics of 'Un manchon interposé de titane réduit-il la fréquence des pseudo-tumeurs après arthrosplatie totale de hanche métal-métal au recul de 5–7 ans'. Together they form a unique fingerprint.

Cite this