Compartment-based reconstruction of 3D acquisition-weighted 31P cardiac magnetic resonance spectroscopic imaging at 7 T: A reproducibility study

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

DOI

  • Andrew Tyler, University of Oxford
  • ,
  • Jane Ellis, University of Oxford
  • ,
  • Justin Y.C. Lau, University of Oxford
  • ,
  • Jack J. Miller
  • Paul A. Bottomley, Johns Hopkins University
  • ,
  • Christopher T. Rodgers, University of Oxford, University of Cambridge
  • ,
  • Damian J. Tyler, University of Oxford
  • ,
  • Ladislav Valkovič, University of Oxford, Slovak Academy of Sciences

Even at 7 T, cardiac 31P magnetic resonance spectroscopic imaging (MRSI) is fundamentally limited by low signal-to-noise ratio (SNR), leading to long scan times and poor temporal and spatial resolutions. Compartment-based reconstruction algorithms such as magnetic resonance spectroscopy with linear algebraic modeling (SLAM) and spectral localization by imaging (SLIM) may improve SNR or reduce scan time without changes to acquisition. Here, we compare the repeatability and SNR performance of these compartment-based methods, applied to three different acquisition schemes at 7 T. Twelve healthy volunteers were scanned twice. Each scan session consisted of a 6.5-min 3D acquisition-weighted (AW) cardiac 31P phase encode-based MRSI acquisition and two 6.5-min truncated k-space acquisitions with increased averaging (4 × 4 × 4 central k-space phase encodes and fractional SLAM [fSLAM] optimized k-space phase encodes). Spectra were reconstructed using (i) AW Fourier reconstruction; (ii) AW SLAM; (iii) AW SLIM; (iv) 4 × 4 × 4 SLAM; (v) 4 × 4 × 4 SLIM; and (vi) fSLAM acquisition–reconstruction combinations. The phosphocreatine-to-adenosine triphosphate (PCr/ATP) ratio, the PCr SNR, and spatial response functions were computed, in addition to coefficients of reproducibility and variability. Using the compartment-based reconstruction algorithms with the AW 31P acquisition resulted in a significant increase in SNR compared with previously published Fourier-based MRSI reconstruction methods while maintaining the measured PCr/ATP ratio and improving interscan reproducibility. The alternative acquisition strategies with truncated k-space performed no better than the common AW approach. Compartment-based spectroscopy approaches provide an attractive reconstruction method for cardiac 31P spectroscopy at 7 T, improving reproducibility and SNR without the need for a dedicated k-space sampling strategy.

Original languageEnglish
Article numbere4950
JournalNMR in Biomedicine
Volume36
Issue9
Number of pages13
ISSN1099-1492
DOIs
Publication statusPublished - Sept 2023

    Research areas

  • P, 7 T, cardiac, SLAM, SLIM, spectroscopy

See relations at Aarhus University Citationformats

ID: 317481211