Annular and subvalvular dynamics after extracellular matrix mitral tube graft implantation in pigs

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

Standard

Annular and subvalvular dynamics after extracellular matrix mitral tube graft implantation in pigs. / Tjørnild, Marcell J; Carlson Hanse, Lisa; Skov, Søren N et al.

In: Interactive Cardiovascular and Thoracic Surgery, Vol. 32, No. 6, 06.2021, p. 978-987.

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{85d2171c827449d0a9044ddf5d0329b2,
title = "Annular and subvalvular dynamics after extracellular matrix mitral tube graft implantation in pigs",
abstract = "OBJECTIVES: Entire mitral valve reconstruction with an extracellular matrix tube graft is a potential candidate to overcome the current limitations of mechanical and bioprosthetic valves. However, clinical data have raised concern with respect to patch failure. The aim of our study was to evaluate the impact of extracellular matrix mitral tube graft implantation on mitral annular and subvalvular regional dynamics in pigs.METHODS: A modified tube graft design made of 2-ply extracellular matrix was used (CorMatrix{\textregistered}; Cardiovascular Inc., Alpharetta, GA, USA). The reconstructions were performed in an acute 80-kg porcine model (N = 8), where each pig acted as its own control. Haemodynamics were assessed with Mikro-Tip pressure catheters and mitral annular and subvalvular geometry and dynamics with sonomicrometry.RESULTS: Catheter-based peak left atrial pressure and pressure difference across the mitral and aortic valves in the reconstructions were comparable to the values seen in the native mitral valves. Also comparable were maximum mitral annular area (755 ± 100 mm2), maximum septal-lateral distance (29.7 ± 1.7 mm), maximum commissure-commissure distance (35.0 ± 3.4 mm), end-systolic annular height-to-commissural width ratio (10.2 ± 1.0%) and end-diastolic interpapillary muscle distance (27.7 ± 3.3 mm). Systolic expansion of the mitral annulus was, however, observed after reconstruction.CONCLUSIONS: The reconstructed mitral valves were fully functional without regurgitation, obstruction or stenosis. The reconstructed mitral annular and subvalvular geometry and subvalvular dynamics were found in the same range to those in the native mitral valve. A regional annular ballooning effect occurred that might predispose to patch failure. However, the greatest risk was found at the papillary muscle attachments.",
author = "Tj{\o}rnild, {Marcell J} and {Carlson Hanse}, Lisa and Skov, {S{\o}ren N} and Poulsen, {Karen B} and Mona Sharghbin and Benhassen, {Leila L} and R{\o}pcke, {Diana M} and Nielsen, {Sten L} and Hasenkam, {J Michael}",
note = "{\textcopyright} The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.",
year = "2021",
month = jun,
doi = "10.1093/icvts/ivab027",
language = "English",
volume = "32",
pages = "978--987",
journal = "Interactive Cardiovascular and Thoracic Surgery",
issn = "1569-9293",
publisher = "Oxford University Press",
number = "6",

}

RIS

TY - JOUR

T1 - Annular and subvalvular dynamics after extracellular matrix mitral tube graft implantation in pigs

AU - Tjørnild, Marcell J

AU - Carlson Hanse, Lisa

AU - Skov, Søren N

AU - Poulsen, Karen B

AU - Sharghbin, Mona

AU - Benhassen, Leila L

AU - Røpcke, Diana M

AU - Nielsen, Sten L

AU - Hasenkam, J Michael

N1 - © The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

PY - 2021/6

Y1 - 2021/6

N2 - OBJECTIVES: Entire mitral valve reconstruction with an extracellular matrix tube graft is a potential candidate to overcome the current limitations of mechanical and bioprosthetic valves. However, clinical data have raised concern with respect to patch failure. The aim of our study was to evaluate the impact of extracellular matrix mitral tube graft implantation on mitral annular and subvalvular regional dynamics in pigs.METHODS: A modified tube graft design made of 2-ply extracellular matrix was used (CorMatrix®; Cardiovascular Inc., Alpharetta, GA, USA). The reconstructions were performed in an acute 80-kg porcine model (N = 8), where each pig acted as its own control. Haemodynamics were assessed with Mikro-Tip pressure catheters and mitral annular and subvalvular geometry and dynamics with sonomicrometry.RESULTS: Catheter-based peak left atrial pressure and pressure difference across the mitral and aortic valves in the reconstructions were comparable to the values seen in the native mitral valves. Also comparable were maximum mitral annular area (755 ± 100 mm2), maximum septal-lateral distance (29.7 ± 1.7 mm), maximum commissure-commissure distance (35.0 ± 3.4 mm), end-systolic annular height-to-commissural width ratio (10.2 ± 1.0%) and end-diastolic interpapillary muscle distance (27.7 ± 3.3 mm). Systolic expansion of the mitral annulus was, however, observed after reconstruction.CONCLUSIONS: The reconstructed mitral valves were fully functional without regurgitation, obstruction or stenosis. The reconstructed mitral annular and subvalvular geometry and subvalvular dynamics were found in the same range to those in the native mitral valve. A regional annular ballooning effect occurred that might predispose to patch failure. However, the greatest risk was found at the papillary muscle attachments.

AB - OBJECTIVES: Entire mitral valve reconstruction with an extracellular matrix tube graft is a potential candidate to overcome the current limitations of mechanical and bioprosthetic valves. However, clinical data have raised concern with respect to patch failure. The aim of our study was to evaluate the impact of extracellular matrix mitral tube graft implantation on mitral annular and subvalvular regional dynamics in pigs.METHODS: A modified tube graft design made of 2-ply extracellular matrix was used (CorMatrix®; Cardiovascular Inc., Alpharetta, GA, USA). The reconstructions were performed in an acute 80-kg porcine model (N = 8), where each pig acted as its own control. Haemodynamics were assessed with Mikro-Tip pressure catheters and mitral annular and subvalvular geometry and dynamics with sonomicrometry.RESULTS: Catheter-based peak left atrial pressure and pressure difference across the mitral and aortic valves in the reconstructions were comparable to the values seen in the native mitral valves. Also comparable were maximum mitral annular area (755 ± 100 mm2), maximum septal-lateral distance (29.7 ± 1.7 mm), maximum commissure-commissure distance (35.0 ± 3.4 mm), end-systolic annular height-to-commissural width ratio (10.2 ± 1.0%) and end-diastolic interpapillary muscle distance (27.7 ± 3.3 mm). Systolic expansion of the mitral annulus was, however, observed after reconstruction.CONCLUSIONS: The reconstructed mitral valves were fully functional without regurgitation, obstruction or stenosis. The reconstructed mitral annular and subvalvular geometry and subvalvular dynamics were found in the same range to those in the native mitral valve. A regional annular ballooning effect occurred that might predispose to patch failure. However, the greatest risk was found at the papillary muscle attachments.

U2 - 10.1093/icvts/ivab027

DO - 10.1093/icvts/ivab027

M3 - Journal article

C2 - 33595082

VL - 32

SP - 978

EP - 987

JO - Interactive Cardiovascular and Thoracic Surgery

JF - Interactive Cardiovascular and Thoracic Surgery

SN - 1569-9293

IS - 6

ER -