Aarhus University Seal

Mika Erik Tapio Sillanpää

Ultra-sensitive biosensor with simultaneous detection (Of cancer and diabetes) and analysis of deformation effects on dielectric rods in optical microstructure

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

DOI

  • Supat Chupradit, Chiang Mai University
  • ,
  • Shameen Ashfaq, Women Medical Officer Punjab Health Department
  • ,
  • Dmitry Bokov, Laboratory of Food Chemistry, Sechenov First Moscow State Medical University
  • ,
  • Wanich Suksatan, Chulabhorn Research Institute
  • ,
  • Abduladheem Turki Jalil, Yanka Kupala State University of Grodno, The Islamic University, Najaf, Kut University College
  • ,
  • Amer M. Alanazi, King Saud University
  • ,
  • Mika Sillanpaa

This study proposes a refractive index sensor for the simultaneous detection of cancer and diabetes based on photonic crystals (PhC). The proposed PhC composed of silicon rods in the air bed arranged in a hexagonal lattice forms the fundamental structure. Two tubes are used to place the cancerous or diabetic samples for measurement. The sensor’s transmission characteristics are simulated and analyzed by solving Maxwell’s electromagnetic equations using the finite-difference time-domain approach for samples being studied. Therefore, diabetes and cancer are detected according to the changes in the refractive index of the samples using the laser source centered at 1550 nm. Considering the findings, the sensor’s geometry changes to adjust the suggested sensitivity and quality factor of structure. According to the results, transmission power ranges between 91 and 100% based on the sample. Moreover, sensitivity ranges from 1294 to 3080 nm/RIU and the maximum Figure of Mertie is nearly FOM = 1550.11 ± 150.11 RIU−1 with the detection in range 31 × 10−6 RIU. In addition, the small area (61.56 µm2) of biosensor results in its appropriateness for different uses in compact photonic integrated circuits. Next, we changed the shape of the dielectric rods and investigated their effects on the sensitivity parameter. The sensitivity and figure of merit after changes in the shape of dielectric rods and nanocavities are at best S = 20,393 nm/RIU and FOM = 9104.017 ± 606.93 RIU−1, receptively. In addition, the resolution detection range is 203.93 × 10−6 RIU.

Original languageEnglish
Article number1564
JournalCoatings
Volume11
Issue12
DOIs
Publication statusPublished - Dec 2021

    Research areas

  • Figure of Mertie (FOM), Simultaneous detection, Square nanocavity, Ultra-sensitive

See relations at Aarhus University Citationformats

ID: 229124843