Aarhus University Seal

June Anita Ejlersen

Observer experience and accuracy of 18F-sodium-fluoride PET/CT for the diagnosis of bone metastases in prostate cancer

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

  • Helle D. Zacho, Aalborg University
  • ,
  • Søren Ravn, Aalborg University
  • ,
  • June A. Ejlersen
  • Joan Fledelius
  • Peter Dolliner, University of Southern Denmark
  • ,
  • Sofie T. Nygaard, University of Southern Denmark
  • ,
  • Paw C. Holdgaard, University of Southern Denmark
  • ,
  • Jeppe F. Lauridsen, University of Southern Denmark
  • ,
  • Christian Haarmark, University of Copenhagen
  • ,
  • Helle W. Hendel, University of Copenhagen
  • ,
  • Lars J. Petersen, Aalborg University

OBJECTIVE: To evaluate the diagnostic accuracy of observers with different levels of experience in reading 18F-sodium fluoride (NaF) PET/CT images for the diagnosis of bone metastases in prostate cancer (PCa) patients. METHODS: Nine observers with varying NaF PET/CT experience, ranging from no experience to 2000+ examinations, evaluated 211 NaF PET/CT scans from PCa patients participating in one of four prospective trials. Each observer evaluated each NaF PET/CT on a patient level using a trichotomous scale: M0 (no bone metastases), Me (equivocal for bone metastases) and M1 (bone metastases). Subsequently, a dichotomous evaluation was conducted (M0/M1). The final diagnosis was retrieved from the original study. For each observer, ROC curves and the diagnostic accuracy were calculated based on dichotomous and trichotomous scales; in the latter case, Me was first regarded as M1 and then M0. RESULTS: Across all experience levels, the sensitivity, specificity and accuracy using the dichotomous scale ranged from 0.81 to 0.89, 0.93 to 1.00 and 0.91 to 0.94, respectively. Employing the trichotomous scale, novice and experienced observers chose Me in up to 20 vs. 10% of cases, respectively. Considering Me as M0, the sensitivity, specificity and accuracy ranged from 0.78 to 0.89, 0.95 to 1.00 and 0.91 to 0.95, respectively. Considering Me as M1, the sensitivity, specificity and accuracy ranged from 0.86 to 0.92, 0.71 to 0.96 and 0.77 to 0.94, respectively. CONCLUSION: Novice observers used the equivocal option more frequently than observers with NaF PET/CT experience. However, on the dichotomous scale, all observers exhibited high and satisfactory accuracy for the detection of bone metastases, making NaF PET/CT an effective imaging modality even in unexperienced hands.

Original languageEnglish
JournalNuclear Medicine Communications
Volume43
Issue6
Pages (from-to)680-686
Number of pages7
DOIs
Publication statusPublished - Jun 2022

Bibliographical note

Publisher Copyright:
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.

See relations at Aarhus University Citationformats

ID: 270652476