Jesper Møller Jensen

Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

Standard

Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography. / Leetmaa, Tina; Hansson, Nicolaj Christopher; Leipsic, Jonathon et al.

In: Circulation. Cardiovascular Interventions (Online), Vol. 8, No. 4, 04.2015.

Research output: Contribution to journal/Conference contribution in journal/Contribution to newspaperJournal articleResearchpeer-review

Harvard

APA

CBE

MLA

Vancouver

Leetmaa T, Hansson NC, Leipsic J, Jensen KT, Poulsen SH, Andersen HR et al. Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography. Circulation. Cardiovascular Interventions (Online). 2015 Apr;8(4). doi: 10.1161/CIRCINTERVENTIONS.114.001596

Author

Leetmaa, Tina ; Hansson, Nicolaj Christopher ; Leipsic, Jonathon et al. / Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography. In: Circulation. Cardiovascular Interventions (Online). 2015 ; Vol. 8, No. 4.

Bibtex

@article{5847d9fe4475468e8541783e7ad0d26c,
title = "Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography",
abstract = "BACKGROUND: Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI.METHODS AND RESULTS: MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis.CONCLUSIONS: Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.",
author = "Tina Leetmaa and Hansson, {Nicolaj Christopher} and Jonathon Leipsic and Jensen, {Kaare Troels} and Poulsen, {Steen H} and Andersen, {Henning R} and Jensen, {Jesper M} and John Webb and Philipp Blanke and Jensen, {Mariann Tang} and N{\o}rgaard, {Bjarne L}",
note = "{\textcopyright} 2015 American Heart Association, Inc.",
year = "2015",
month = apr,
doi = "10.1161/CIRCINTERVENTIONS.114.001596",
language = "English",
volume = "8",
journal = "Circulation: Cardiovascular Interventions",
issn = "1941-7640",
publisher = "LIPPINCOTT WILLIAMS & WILKINS",
number = "4",

}

RIS

TY - JOUR

T1 - Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography

AU - Leetmaa, Tina

AU - Hansson, Nicolaj Christopher

AU - Leipsic, Jonathon

AU - Jensen, Kaare Troels

AU - Poulsen, Steen H

AU - Andersen, Henning R

AU - Jensen, Jesper M

AU - Webb, John

AU - Blanke, Philipp

AU - Jensen, Mariann Tang

AU - Nørgaard, Bjarne L

N1 - © 2015 American Heart Association, Inc.

PY - 2015/4

Y1 - 2015/4

N2 - BACKGROUND: Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI.METHODS AND RESULTS: MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis.CONCLUSIONS: Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.

AB - BACKGROUND: Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI.METHODS AND RESULTS: MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis.CONCLUSIONS: Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.

U2 - 10.1161/CIRCINTERVENTIONS.114.001596

DO - 10.1161/CIRCINTERVENTIONS.114.001596

M3 - Journal article

C2 - 25873726

VL - 8

JO - Circulation: Cardiovascular Interventions

JF - Circulation: Cardiovascular Interventions

SN - 1941-7640

IS - 4

ER -