Long-term forecasting of hourly district heating loads in urban areas using hierarchical archetype modeling

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

Standard

Long-term forecasting of hourly district heating loads in urban areas using hierarchical archetype modeling. / Kristensen, Martin Heine; Hedegaard, Rasmus Elbæk; Petersen, Steffen.

I: Energy, Bind 201, 117687, 06.2020.

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{448a23a089bc4524a9746ae1b7cc54f4,
title = "Long-term forecasting of hourly district heating loads in urban areas using hierarchical archetype modeling",
abstract = "This paper demonstrates and validates the application of a recently proposed archetype modeling and calibration framework for setting up 11 stochastic archetype building energy models of Danish detached single-family houses (SFH's). For this task, the municipal district heating system of Aarhus, Denmark, and its associated building stock were employed as case study, together comprising a dataset of 18 475 SFH's with hourly time series heating data for two years (2017–2018). The 11 physics-based archetype models were each calibrated using a training building sample with data from a one-year calibration period (2017) and tested for their ability to forecast the heat load of another building sample in a previously unseen one-year validation period (2018). The calibrated archetype models were further tested for their joint forecasting ability to match the aggregated heat load of six suburban dwelling areas of different composition and location within the city region of Aarhus, and finally for their ability to forecast the entire citywide dataset of 18 475 SFH's. The modeling framework performs very well for the aggregated citywide predictions with a practically non-existent bias of the overall heat load during the validation period (NMBE < 0.5%) and with only moderate inaccuracies present in hourly load predictions (MAPE < 12%). The high forecasting accuracy validates the application of the demonstrated archetype modeling framework for long-term urban-scale predictions; however, analysis of the time series errors indicate that the performance could be further improved by focusing on a better representation of the holiday periods and by ensuring the training data to be adequately informative to enable a good calibration of the model parameters. The simplicity of the archetype models coupled with the applied physics-based model structure makes the framework suitable for general energy planning purposes. By adapting a more dynamic model structure, it would also be possible to apply the framework for more complex analysis of, for instance, the urban-scale demand response and the general heating flexibility of the building stock.",
keywords = "4GDH, Building archetypes, District heating, Energy planning and management, Heat load forecast, Hierarchical modeling, Smart metering data, Urban building energy modeling",
author = "Kristensen, {Martin Heine} and Hedegaard, {Rasmus Elb{\ae}k} and Steffen Petersen",
year = "2020",
month = jun,
doi = "10.1016/j.energy.2020.117687",
language = "English",
volume = "201",
journal = "Energy",
issn = "0360-5442",
publisher = "Elsevier Ltd",

}

RIS

TY - JOUR

T1 - Long-term forecasting of hourly district heating loads in urban areas using hierarchical archetype modeling

AU - Kristensen, Martin Heine

AU - Hedegaard, Rasmus Elbæk

AU - Petersen, Steffen

PY - 2020/6

Y1 - 2020/6

N2 - This paper demonstrates and validates the application of a recently proposed archetype modeling and calibration framework for setting up 11 stochastic archetype building energy models of Danish detached single-family houses (SFH's). For this task, the municipal district heating system of Aarhus, Denmark, and its associated building stock were employed as case study, together comprising a dataset of 18 475 SFH's with hourly time series heating data for two years (2017–2018). The 11 physics-based archetype models were each calibrated using a training building sample with data from a one-year calibration period (2017) and tested for their ability to forecast the heat load of another building sample in a previously unseen one-year validation period (2018). The calibrated archetype models were further tested for their joint forecasting ability to match the aggregated heat load of six suburban dwelling areas of different composition and location within the city region of Aarhus, and finally for their ability to forecast the entire citywide dataset of 18 475 SFH's. The modeling framework performs very well for the aggregated citywide predictions with a practically non-existent bias of the overall heat load during the validation period (NMBE < 0.5%) and with only moderate inaccuracies present in hourly load predictions (MAPE < 12%). The high forecasting accuracy validates the application of the demonstrated archetype modeling framework for long-term urban-scale predictions; however, analysis of the time series errors indicate that the performance could be further improved by focusing on a better representation of the holiday periods and by ensuring the training data to be adequately informative to enable a good calibration of the model parameters. The simplicity of the archetype models coupled with the applied physics-based model structure makes the framework suitable for general energy planning purposes. By adapting a more dynamic model structure, it would also be possible to apply the framework for more complex analysis of, for instance, the urban-scale demand response and the general heating flexibility of the building stock.

AB - This paper demonstrates and validates the application of a recently proposed archetype modeling and calibration framework for setting up 11 stochastic archetype building energy models of Danish detached single-family houses (SFH's). For this task, the municipal district heating system of Aarhus, Denmark, and its associated building stock were employed as case study, together comprising a dataset of 18 475 SFH's with hourly time series heating data for two years (2017–2018). The 11 physics-based archetype models were each calibrated using a training building sample with data from a one-year calibration period (2017) and tested for their ability to forecast the heat load of another building sample in a previously unseen one-year validation period (2018). The calibrated archetype models were further tested for their joint forecasting ability to match the aggregated heat load of six suburban dwelling areas of different composition and location within the city region of Aarhus, and finally for their ability to forecast the entire citywide dataset of 18 475 SFH's. The modeling framework performs very well for the aggregated citywide predictions with a practically non-existent bias of the overall heat load during the validation period (NMBE < 0.5%) and with only moderate inaccuracies present in hourly load predictions (MAPE < 12%). The high forecasting accuracy validates the application of the demonstrated archetype modeling framework for long-term urban-scale predictions; however, analysis of the time series errors indicate that the performance could be further improved by focusing on a better representation of the holiday periods and by ensuring the training data to be adequately informative to enable a good calibration of the model parameters. The simplicity of the archetype models coupled with the applied physics-based model structure makes the framework suitable for general energy planning purposes. By adapting a more dynamic model structure, it would also be possible to apply the framework for more complex analysis of, for instance, the urban-scale demand response and the general heating flexibility of the building stock.

KW - 4GDH

KW - Building archetypes

KW - District heating

KW - Energy planning and management

KW - Heat load forecast

KW - Hierarchical modeling

KW - Smart metering data

KW - Urban building energy modeling

UR - http://www.scopus.com/inward/record.url?scp=85083879719&partnerID=8YFLogxK

U2 - 10.1016/j.energy.2020.117687

DO - 10.1016/j.energy.2020.117687

M3 - Journal article

AN - SCOPUS:85083879719

VL - 201

JO - Energy

JF - Energy

SN - 0360-5442

M1 - 117687