Inter-fraction motion robustness in a prospective phase II trial on dose-escalated proton reirradiation for locally recurrent rectal cancer

C. G. Truelsen*, H. S. Rønde, J. F. Kallehauge, L. Poulsen, B. M. Havelund, B. G. Pedersen, L. H. Iversen, K. G. Spindler, C. S. Kronborg

*Corresponding author af dette arbejde

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

1 Citationer (Scopus)

Abstract

Background and purpose: Intensity modulated proton therapy (IMPT) enables generation of conformal dose plans with organ at risk (OAR) sparing potential. However, pelvic IMPT robustness is challenged by inter-fraction motion caused by constant anatomical variations. In this study, the dosimetric impact of inter-fraction motion on target coverage and dose to OAR was quantified in the prospective phase II study ReRad-II on dose-escalated proton reirradiation for locally recurrent rectal cancer (LRRC). Materials and methods: The inter-fraction motion robustness was assessed for the initial twelve patients enrolled in the ReRad-II study. Patients with resectable LRRC were assessed for neoadjuvant IMPT (55 Gy(RBE)/44Fx) and unresectable recurrences for definitive IMPT (57.5–65 Gy(RBE)/ 46-52Fx). Target coverage and dose to OAR were assessed for robustly optimised three-field IMPT, on 12 plan computerized tomography (CT) scans (pCT) − and 47 repetitive control CT scans (cCTs) during the treatment. The target coverage and doses to OAR were re-calculated on each cCT and the mean dose ratio (pCT/cCT-ratio) and target coverage (V95%) was evaluated. Results: The target coverage was robust with a mean dose pCT/cCT-ratio of 1.00 (+/-1%). The V95% target coverage for every cCT were above the accepted worst-case scenario in the robust evaluation. Considerable variation in bladder-, bowel bag-, and bowel loop volume was observed. The OAR with the largest variation in ratio was the bladder (pCT/cCT-ratio: 1.3 (range: 0.5–4.7). Conclusions: IMPT for dose-escalated reirradiation of LRRC provided anatomically robust target coverage despite OAR changes. Inter-fraction motion resulted in OAR doses varying within clinically acceptable range.

OriginalsprogEngelsk
Artikelnummer100634
TidsskriftPhysics and Imaging in Radiation Oncology
Vol/bind31
Antal sider7
ISSN2405-6316
DOI
StatusUdgivet - jul. 2024

Fingeraftryk

Dyk ned i forskningsemnerne om 'Inter-fraction motion robustness in a prospective phase II trial on dose-escalated proton reirradiation for locally recurrent rectal cancer'. Sammen danner de et unikt fingeraftryk.

Citationsformater