Delineation uncertainties of tumour volumes on MRI of head and neck cancer patients

Ruta Zukauskaite*, Christopher N. Rumley, Christian R. Hansen, Michael G. Jameson, Yuvnik Trada, Jørgen Johansen, Niels Gyldenkerne, Jesper G. Eriksen, Farhannah Aly, Rasmus L. Christensen, Mark Lee, Carsten Brink, Lois Holloway

*Corresponding author af dette arbejde

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

Abstract

Background: During the last decade, radiotherapy using MR Linac has gone from research to clinical implementation for different cancer locations. For head and neck cancer (HNC), target delineation based only on MR images is not yet standard, and the utilisation of MRI instead of PET/CT in radiotherapy planning is not well established. We aimed to analyse the inter-observer variation (IOV) in delineating GTV (gross tumour volume) on MR images only for patients with HNC. Material/methods: 32 HNC patients from two independent departments were included. Four clinical oncologists from Denmark and four radiation oncologists from Australia had independently contoured primary tumour GTVs (GTV-T) and nodal GTVs (GTV-N) on T2-weighted MR images obtained at the time of treatment planning. Observers were provided with sets of images, delineation guidelines and patient synopsis. Simultaneous truth and performance level estimation (STAPLE) reference volumes were generated for each structure using all observer contours. The IOV was assessed using the DICE Similarity Coefficient (DSC) and mean absolute surface distance (MASD). Results: 32 GTV-Ts and 68 GTV-Ns were contoured per observer. The median MASD for GTV-Ts and GTV-Ns across all patients was 0.17 cm (range 0.08–0.39 cm) and 0.07 cm (range 0.04–0.33 cm), respectively. Median DSC relative to a STAPLE volume for GTV-Ts and GTV-Ns across all patients were 0.73 and 0.76, respectively. A significant correlation was seen between median DSCs and median volumes of GTV-Ts (Spearman correlation coefficient 0.76, p < 0.001) and of GTV-Ns (Spearman correlation coefficient 0.55, p < 0.001). Conclusion: Contouring GTVs in patients with HNC on MRI showed that the median IOV for GTV-T and GTV-N was below 2 mm, based on observes from two separate radiation departments. However, there are still specific regions in tumours that are difficult to resolve as either malignant tissue or oedema that potentially could be improved by further training in MR-only delineation.

OriginalsprogEngelsk
TidsskriftClinical and Translational Radiation Oncology
Vol/bind36
Sider (fra-til)121-126
Antal sider6
ISSN2405-6308
DOI
StatusUdgivet - sep. 2022

Fingeraftryk

Dyk ned i forskningsemnerne om 'Delineation uncertainties of tumour volumes on MRI of head and neck cancer patients'. Sammen danner de et unikt fingeraftryk.

Citationsformater