T1 - Delineation uncertainties of tumour volumes on MRI of head and neck cancer patients
AU - Zukauskaite, Ruta
AU - Rumley, Christopher N.
AU - Hansen, Christian R.
AU - Jameson, Michael G.
AU - Trada, Yuvnik
AU - Johansen, Jørgen
AU - Gyldenkerne, Niels
AU - Eriksen, Jesper G.
AU - Aly, Farhannah
AU - Christensen, Rasmus L.
AU - Lee, Mark
AU - Brink, Carsten
AU - Holloway, Lois
PY - 2022/9
Y1 - 2022/9
N2 - Background: During the last decade, radiotherapy using MR Linac has gone from research to clinical implementation for different cancer locations. For head and neck cancer (HNC), target delineation based only on MR images is not yet standard, and the utilisation of MRI instead of PET/CT in radiotherapy planning is not well established. We aimed to analyse the inter-observer variation (IOV) in delineating GTV (gross tumour volume) on MR images only for patients with HNC. Material/methods: 32 HNC patients from two independent departments were included. Four clinical oncologists from Denmark and four radiation oncologists from Australia had independently contoured primary tumour GTVs (GTV-T) and nodal GTVs (GTV-N) on T2-weighted MR images obtained at the time of treatment planning. Observers were provided with sets of images, delineation guidelines and patient synopsis. Simultaneous truth and performance level estimation (STAPLE) reference volumes were generated for each structure using all observer contours. The IOV was assessed using the DICE Similarity Coefficient (DSC) and mean absolute surface distance (MASD). Results: 32 GTV-Ts and 68 GTV-Ns were contoured per observer. The median MASD for GTV-Ts and GTV-Ns across all patients was 0.17 cm (range 0.08–0.39 cm) and 0.07 cm (range 0.04–0.33 cm), respectively. Median DSC relative to a STAPLE volume for GTV-Ts and GTV-Ns across all patients were 0.73 and 0.76, respectively. A significant correlation was seen between median DSCs and median volumes of GTV-Ts (Spearman correlation coefficient 0.76, p < 0.001) and of GTV-Ns (Spearman correlation coefficient 0.55, p < 0.001). Conclusion: Contouring GTVs in patients with HNC on MRI showed that the median IOV for GTV-T and GTV-N was below 2 mm, based on observes from two separate radiation departments. However, there are still specific regions in tumours that are difficult to resolve as either malignant tissue or oedema that potentially could be improved by further training in MR-only delineation.
AB - Background: During the last decade, radiotherapy using MR Linac has gone from research to clinical implementation for different cancer locations. For head and neck cancer (HNC), target delineation based only on MR images is not yet standard, and the utilisation of MRI instead of PET/CT in radiotherapy planning is not well established. We aimed to analyse the inter-observer variation (IOV) in delineating GTV (gross tumour volume) on MR images only for patients with HNC. Material/methods: 32 HNC patients from two independent departments were included. Four clinical oncologists from Denmark and four radiation oncologists from Australia had independently contoured primary tumour GTVs (GTV-T) and nodal GTVs (GTV-N) on T2-weighted MR images obtained at the time of treatment planning. Observers were provided with sets of images, delineation guidelines and patient synopsis. Simultaneous truth and performance level estimation (STAPLE) reference volumes were generated for each structure using all observer contours. The IOV was assessed using the DICE Similarity Coefficient (DSC) and mean absolute surface distance (MASD). Results: 32 GTV-Ts and 68 GTV-Ns were contoured per observer. The median MASD for GTV-Ts and GTV-Ns across all patients was 0.17 cm (range 0.08–0.39 cm) and 0.07 cm (range 0.04–0.33 cm), respectively. Median DSC relative to a STAPLE volume for GTV-Ts and GTV-Ns across all patients were 0.73 and 0.76, respectively. A significant correlation was seen between median DSCs and median volumes of GTV-Ts (Spearman correlation coefficient 0.76, p < 0.001) and of GTV-Ns (Spearman correlation coefficient 0.55, p < 0.001). Conclusion: Contouring GTVs in patients with HNC on MRI showed that the median IOV for GTV-T and GTV-N was below 2 mm, based on observes from two separate radiation departments. However, there are still specific regions in tumours that are difficult to resolve as either malignant tissue or oedema that potentially could be improved by further training in MR-only delineation.
KW - Head and neck cancer
KW - Inter-observer variation
KW - MRI
KW - Target delineation
UR - http://www.scopus.com/inward/record.url?scp=85135814353&partnerID=8YFLogxK
U2 - 10.1016/j.ctro.2022.08.005
DO - 10.1016/j.ctro.2022.08.005
M3 - Journal article
C2 - 36017132
AN - SCOPUS:85135814353
SN - 2405-6308
VL - 36
SP - 121
EP - 126
JO - Clinical and Translational Radiation Oncology
JF - Clinical and Translational Radiation Oncology
ER -