COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

Standard

COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES. / Husted, S.; Ingerslev, H. J.

I: Acta pathologica et microbiologica Scandinavica. Section C, Immunology, Bind 83 C, Nr. 5, 01.01.1975, s. 347-353.

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

Harvard

Husted, S & Ingerslev, HJ 1975, 'COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES', Acta pathologica et microbiologica Scandinavica. Section C, Immunology, bind 83 C, nr. 5, s. 347-353. https://doi.org/10.1111/j.1699-0463.1975.tb01649.x

APA

Husted, S., & Ingerslev, H. J. (1975). COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES. Acta pathologica et microbiologica Scandinavica. Section C, Immunology, 83 C(5), 347-353. https://doi.org/10.1111/j.1699-0463.1975.tb01649.x

CBE

Husted S, Ingerslev HJ. 1975. COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES. Acta pathologica et microbiologica Scandinavica. Section C, Immunology. 83 C(5):347-353. https://doi.org/10.1111/j.1699-0463.1975.tb01649.x

MLA

Husted, S. og H. J. Ingerslev. "COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES". Acta pathologica et microbiologica Scandinavica. Section C, Immunology. 1975, 83 C(5). 347-353. https://doi.org/10.1111/j.1699-0463.1975.tb01649.x

Vancouver

Husted S, Ingerslev HJ. COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES. Acta pathologica et microbiologica Scandinavica. Section C, Immunology. 1975 jan 1;83 C(5):347-353. https://doi.org/10.1111/j.1699-0463.1975.tb01649.x

Author

Husted, S. ; Ingerslev, H. J. / COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES. I: Acta pathologica et microbiologica Scandinavica. Section C, Immunology. 1975 ; Bind 83 C, Nr. 5. s. 347-353.

Bibtex

@article{f651944428a943dfa98d99bddef38b3e,
title = "COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES",
abstract = "A sperm‐immobilization test, a sperm‐cytotoxicity test and a microtechnique for simultaneous detection of immobilizing and cytotoxic sperm antibodies have been compared. The immobilization test and the microtechnique were easy to use. In order to ensure reliable results of the cytotoxicity test, the evaluation of a serum had to be based on the mean spermotoxic index (STI) of three experiments. The cytotoxicity test was therefore found to be more time‐consuming and less suitable for large‐scale examinations. Among 30 sera from men with sperm agglu‐tinins, all sera with titres >64 yielded positive results by all three techniques, whereas minor differences were found in sera with lower agglutinin titres. A comparison of the tests showed that, except for one case, cytotoxic activity was observed only in sera which also had immobilizing activity and, using the microtechnique, this was observed without exception. A total of 103 sera without agglutinins revealed negative results by the three techniques. Titration of positive sera in the immobilization test and in the microtechnique using guinea‐pig and human serum, respectively, as the source of complement, showed identical results if the actual dilution of test serum in the test mixture was taken into account. 1975 Acta Pathologica, Microbiologica et Immunologica Scandinavica",
keywords = "comparison, cytotoxic, detection methods, immobilizing, Sperm antibodies",
author = "S. Husted and Ingerslev, {H. J.}",
year = "1975",
month = jan,
day = "1",
doi = "10.1111/j.1699-0463.1975.tb01649.x",
language = "English",
volume = "83 C",
pages = "347--353",
journal = "Acta pathologica et microbiologica Scandinavica. Section C, Immunology",
issn = "0304-1328",
publisher = "Wiley-Blackwell",
number = "5",

}

RIS

TY - JOUR

T1 - COMPARISON OF METHODS FOR THE DETECTION OF IMMOBILIZING AND CYTOTOXIC SPERM ANTIBODIES

AU - Husted, S.

AU - Ingerslev, H. J.

PY - 1975/1/1

Y1 - 1975/1/1

N2 - A sperm‐immobilization test, a sperm‐cytotoxicity test and a microtechnique for simultaneous detection of immobilizing and cytotoxic sperm antibodies have been compared. The immobilization test and the microtechnique were easy to use. In order to ensure reliable results of the cytotoxicity test, the evaluation of a serum had to be based on the mean spermotoxic index (STI) of three experiments. The cytotoxicity test was therefore found to be more time‐consuming and less suitable for large‐scale examinations. Among 30 sera from men with sperm agglu‐tinins, all sera with titres >64 yielded positive results by all three techniques, whereas minor differences were found in sera with lower agglutinin titres. A comparison of the tests showed that, except for one case, cytotoxic activity was observed only in sera which also had immobilizing activity and, using the microtechnique, this was observed without exception. A total of 103 sera without agglutinins revealed negative results by the three techniques. Titration of positive sera in the immobilization test and in the microtechnique using guinea‐pig and human serum, respectively, as the source of complement, showed identical results if the actual dilution of test serum in the test mixture was taken into account. 1975 Acta Pathologica, Microbiologica et Immunologica Scandinavica

AB - A sperm‐immobilization test, a sperm‐cytotoxicity test and a microtechnique for simultaneous detection of immobilizing and cytotoxic sperm antibodies have been compared. The immobilization test and the microtechnique were easy to use. In order to ensure reliable results of the cytotoxicity test, the evaluation of a serum had to be based on the mean spermotoxic index (STI) of three experiments. The cytotoxicity test was therefore found to be more time‐consuming and less suitable for large‐scale examinations. Among 30 sera from men with sperm agglu‐tinins, all sera with titres >64 yielded positive results by all three techniques, whereas minor differences were found in sera with lower agglutinin titres. A comparison of the tests showed that, except for one case, cytotoxic activity was observed only in sera which also had immobilizing activity and, using the microtechnique, this was observed without exception. A total of 103 sera without agglutinins revealed negative results by the three techniques. Titration of positive sera in the immobilization test and in the microtechnique using guinea‐pig and human serum, respectively, as the source of complement, showed identical results if the actual dilution of test serum in the test mixture was taken into account. 1975 Acta Pathologica, Microbiologica et Immunologica Scandinavica

KW - comparison

KW - cytotoxic

KW - detection methods

KW - immobilizing

KW - Sperm antibodies

UR - http://www.scopus.com/inward/record.url?scp=0016750367&partnerID=8YFLogxK

U2 - 10.1111/j.1699-0463.1975.tb01649.x

DO - 10.1111/j.1699-0463.1975.tb01649.x

M3 - Journal article

AN - SCOPUS:0016750367

VL - 83 C

SP - 347

EP - 353

JO - Acta pathologica et microbiologica Scandinavica. Section C, Immunology

JF - Acta pathologica et microbiologica Scandinavica. Section C, Immunology

SN - 0304-1328

IS - 5

ER -