Rubens Spin-Neto

Mechanical evaluation of six techniques for stable fixation of the sagittal split osteotomy after counterclockwise mandibular advancement

Publikation: Bidrag til tidsskrift/Konferencebidrag i tidsskrift /Bidrag til avisTidsskriftartikelForskningpeer review

DOI

  • Leandro Benetti De Oliveira, Dental School at Araraquara, Oral and Maxillofacial Surgery Division, São Paulo State University – UNESP, Araraquara, São Paulo, Brazil, Brasilien
  • Jose Mauricio Nunes Reis, Dental School at Araraquara, Department of Prosthodontics, São Paulo State University – UNESP, Araraquara, São Paulo, Brazil, Brasilien
  • Rubens Spin-Neto
  • Marisa Aparecida Cabrini Gabrielli, Dental School at Araraquara, Oral and Maxillofacial Surgery Division, São Paulo State University – UNESP, Araraquara, São Paulo, Brazil, Brasilien
  • Yener Oguz, Maktoum Bin Hamdan Dental University College, Dubai, United Arab Emirates, United Arab Emirates
  • Valfrido Antonio Pereira-Filho, Dental School at Araraquara, Oral and Maxillofacial Surgery Division, São Paulo State University – UNESP, Araraquara, São Paulo, Brazil, Brasilien

We have evaluated the resistance to displacement of six stable methods of fixation of a sagittal split ramus osteotomy (SSRO) in the mandibular advancement with counterclockwise rotation. We tested 60 synthetic hemimandibles in six groups of 10 each: Group I - fixation with a straight four-hole 2.0mm miniplate; Group II - a straight six-hole 2.0mm miniplate; Group III - two straight 2.0mm four-hole miniplates; Group IV - an eight-hole 2.0mm (grid plate); Group V - a 2.0mm four-hole straight miniplate and 2.0×12mm bicortical screw; and Group VI - a straight four-hole 2.0mm locking miniplate. We applied a linear force in the region between the canine and the first premolar using a universal testing machine (EMIC- DL2000) with a loading cell of 10 KN. The loads at 1, 3, and 5mm displacement were recorded (N) and the data transmitted from the load cell to a computer. Results were analysed using analysis of variance (ANOVA) (p<0.001) and the Tukey post-test for comparison of the significance of the differences between the groups. For the three degrees of displacement, fixation with two straight 2.0mm plates and with the grid plate gave higher load values.

OriginalsprogEngelsk
TidsskriftBritish Journal of Oral and Maxillofacial Surgery
Sider (fra-til)573-578
Antal sider6
ISSN0266-4356
DOI
StatusUdgivet - 7 apr. 2016

Se relationer på Aarhus Universitet Citationsformater

ID: 99412551